Reversing Valve - Operation

Operation

The reversing valve has two states, relaxed and energized. The energized state is typically achieved by applying 24 volts of alternating current, which is commonly used in HVAC . The heat pump can be designed by the manufacturer to produce cooling or heating with the reversing valve in the relaxed state. When the reversing valve is energized, it will produce the opposite conditioning. In other words, a reversing valve installed in such a way as to produce cooling when relaxed will produce heating when energized. Likewise, a reversing valve installed to produce heating when relaxed will produce cooling when energized.

Read more about this topic:  Reversing Valve

Famous quotes containing the word operation:

    It is critical vision alone which can mitigate the unimpeded operation of the automatic.
    Marshall McLuhan (1911–1980)

    It requires a surgical operation to get a joke well into a Scotch understanding. The only idea of wit, or rather that inferior variety of the electric talent which prevails occasionally in the North, and which, under the name of “Wut,” is so infinitely distressing to people of good taste, is laughing immoderately at stated intervals.