Noise Regulation - Building Codes

Building Codes

In the case of construction of new (or remodeled) apartments, condominiums, hospitals and hotels, many U.S. states and cities have stringent building codes with requirements of acoustical analysis, in order to protect building occupants from exterior noise sources and sound generated within the building itself. With regard to exterior noise, the codes usually require measurement of the exterior acoustic environment in order to determine the performance standard required for exterior building skin design. The architect can work with the acoustical scientist to arrive at the best cost-effective means of creating a quiet interior (normally 45 dBA). The most important elements of design of the building skin are usually: glazing (glass thickness, double pane design, etc.), roof material, caulking standards, chimney baffles, exterior door design, mail slots, attic ventilation ports and mounting of through the wall air conditioners. A special case of building skin design arises in the case of aircraft noise, where the FAA has funded extensive work in residential retrofit.

Regarding sound generated inside the building, there are two principal types of transmission. First, airborne sound travels through walls or floor/ceiling assemblies and can emanate from either human activities in adjacent living spaces or from mechanical noise within the building systems. Human activities might include voice, amplified sound systems or animal noise. Mechanical systems are elevator systems, boilers, refrigeration or air conditioning systems, generators and trash compactors. Since many of these sounds are inherently loud, the principle of regulation is to require the wall or ceiling assembly to meet certain performance standards (typically Sound Transmission Class of 50), which allows considerable attenuation of the sound level reaching occupants.

The second type of interior sound is called Impact Insulation Class (IIC) transmission. This effect arises not from airborne transmission, but rather from transmission of sound through the building itself. The most common perception of IIC noise is from footfall of occupants in living spaces above. This type of noise is somewhat more difficult to abate, but consideration must be given to isolating the floor assembly above or hanging the lower ceiling on resilient channel. Commonly a performance standard of IIC equal to 50 is specified in building codes. California has generally led the U.S. in widespread application of building code requirements for sound transmission; accordingly, the level of protection for building occupants has increased markedly in the last several decades.

Read more about this topic:  Noise Regulation

Famous quotes containing the words building and/or codes:

    The mention of one apartment in a building naturally introduces an enquiry or discourse concerning the others: and if we think of a wound, we can scarcely forbear reflecting on the pain which follows it.
    David Hume (1711–1776)

    I cannot help thinking that the menace of Hell makes as many devils as the severe penal codes of inhuman humanity make villains.
    George Gordon Noel Byron (1788–1824)