AC Motor - Wound Rotors

Wound Rotors

An alternate design, called the wound rotor, is used when variable speed is required. In this case, the rotor has the same number of poles as the stator and the windings are made of wire, connected to slip rings on the shaft. Carbon brushes connect the slip rings to an external controller such as a variable resistor that allows changing the motor's slip rate. In certain high-power variable speed wound-rotor drives, the slip-frequency energy is captured, rectified and returned to the power supply through an inverter. With bidirectionally controlled power, the wound-rotor becomes an active participant in the energy conversion process with the wound-rotor doubly fed configuration showing twice the power density.

Compared to squirrel cage rotors and without considering brushless wound-rotor doubly fed technology, wound rotor motors are expensive and require maintenance of the slip rings and brushes, but they were the standard form for variable speed control before the advent of compact power electronic devices. Transistorized inverters with variable-frequency drive can now be used for speed control, and wound rotor motors are becoming less common.

Several methods of starting a polyphase motor are used. Where the large inrush current and high starting torque can be permitted, the motor can be started across the line, by applying full line voltage to the terminals (direct-on-line, DOL). Where it is necessary to limit the starting inrush current (where the motor is large compared with the short-circuit capacity of the supply), reduced voltage starting using either series inductors, an autotransformer, thyristors, or other devices are used. A technique sometimes used is (star-delta, YΔ) starting, where the motor coils are initially connected in star for acceleration of the load, then switched to delta when the load is up to speed. This technique is more common in Europe than in North America. Transistorized drives can directly vary the applied voltage as required by the starting characteristics of the motor and load.

This type of motor is becoming more common in traction applications such as locomotives, where it is known as the asynchronous traction motor.

The speed of the AC motor is determined primarily by the frequency of the AC supply and the number of poles in the stator winding, according to the relation:

where

Ns = Synchronous speed, in revolutions per minute
F = AC power frequency
p = Number of poles per phase winding

Actual RPM for an induction motor will be less than this calculated synchronous speed by an amount known as slip, that increases with the torque produced. With no load, the speed will be very close to synchronous. When loaded, standard motors have between 2-3% slip, special motors may have up to 7% slip, and a class of motors known as torque motors are rated to operate at 100% slip (0 RPM/full stall).

The slip of the AC motor is calculated by:

where

Nr = Rotational speed, in revolutions per minute.
S = Normalised Slip, 0 to 1.

As an example, a typical four-pole motor running on 60 Hz might have a nameplate rating of 1725 RPM at full load, while its calculated speed is 1800 RPM.

The speed in this type of motor has traditionally been altered by having additional sets of coils or poles in the motor that can be switched on and off to change the speed of magnetic field rotation. However, developments in power electronics mean that the frequency of the power supply can also now be varied to provide a smoother control of the motor speed.

This kind of rotor is the basic hardware for induction regulators, which is an exception of the use of rotating magnetic field as pure electrical (not electromechanical) application.

Read more about this topic:  AC Motor

Famous quotes containing the word wound:

    We cannot assume the injustice of any actions which only create offense, and especially as regards religion and morals. He who utters or does anything to wound the conscience and moral sense of others, may indeed act immorally; but, so long as he is not guilty of being importunate, he violates no right.