Radar Cross-section - Measurement

Measurement

Measurement of a target's RCS is performed at a radar reflectivity range or scattering range. The first type of range is an outdoor range where the target is positioned on a specially shaped low RCS pylon some distance down-range from the transmitters. Such a range eliminates the need for placing radar absorbers behind the target, however multi-path interactions with the ground must be mitigated.

An anechoic chamber is also commonly used. In such a room, the target is placed on a rotating pillar in the center, and the walls, floors and ceiling are covered by stacks of radar absorbing material. These absorbers prevent corruption of the measurement due to reflections. A compact range is an anechoic chamber with a reflector to simulate far field conditions.