Application
Optical fiber connectors are used to join optical fibers where a connect/disconnect capability is required. The basic connector unit is a connector assembly. A connector assembly consists of an adapter and two connector plugs. Due to the polishing and tuning procedures that may be incorporated into optical connector manufacturing, connectors are generally assembled onto optical fiber in a supplier’s manufacturing facility. However, the assembly and polishing operations involved can be performed in the field, for example, to make cross-connect jumpers to size.
Optical fiber connectors are used in telephone company central offices, at installations on customer premises, and in outside plant applications to connect equipment and cables, or to cross-connect cables.
Most optical fiber connectors are spring-loaded, so the fiber faces are pressed together when the connectors are mated. The resulting glass-to-glass or plastic-to-plastic contact eliminates signal losses that would be caused by an air gap between the joined fibers.
Every fiber connection has two values:
- Attenuation or insertion loss
- Reflection or return loss.
Measurements of these parameters are now defined in IEC standard 61753-1. The standard gives five grades for insertion loss from A (best) to D (worst), and M for multimode. The other parameter is return loss, with grades from 1 (best) to 5 (worst).
A variety of optical fiber connectors are available, but SC and LC connectors are the most common types of connectors on the market. Typical connectors are rated for 500–1,000 mating cycles. The main differences among types of connectors are dimensions and methods of mechanical coupling. Generally, organizations will standardize on one kind of connector, depending on what equipment they commonly use. Different connectors are required for multimode, and for single-mode fibers.
In many data center applications, small (e.g., LC) and multi-fiber (e.g., MTP) connectors are replacing larger, older styles (e.g., SC), allowing more fiber ports per unit of rack space.
Features of good connector design:
- Low insertion loss
- High return loss (low amounts of reflection at the interface)
- Ease of installation
- Low cost
- Reliability
- Low environmental sensitivity
- Ease of use
Outside plant applications may require connectors be located underground, or on outdoor walls or utility poles. In such settings, protective enclosures are often used, and fall into two broad categories: hermetic (sealed) and free-breathing. Hermetic cases prevent entry of moisture and air but, lacking ventilation, can become hot if exposed to sunlight or other sources of heat. Free-breathing enclosures, on the other hand, allow ventilation, but can also admit moisture, insects and airborne contaminants. Selection of the correct housing depends on the cable and connector type, the location, and environmental factors. Careful assembly is required to ensure good protection against the elements.
Depending on user requirements, housings for outside plant applications may be tested by the manufacturer under various environmental simulations, which could include physical shock and vibration, water spray, water immersion, dust, etc. to ensure the integrity of optical fiber connections and housing seals.
Read more about this topic: Optical Fiber Connector
Famous quotes containing the word application:
“The best political economy is the care and culture of men; for, in these crises, all are ruined except such as are proper individuals, capable of thought, and of new choice and the application of their talent to new labor.”
—Ralph Waldo Emerson (18031882)
“We will not be imposed upon by this vast application of forces. We believe that most things will have to be accomplished still by the application called Industry. We are rather pleased, after all, to consider the small private, but both constant and accumulated, force which stands behind every spade in the field. This it is that makes the valleys shine, and the deserts really bloom.”
—Henry David Thoreau (18171862)
“Five oclock tea is a phrase our rude forefathers, even of the last generation, would scarcely have understood, so completely is it a thing of to-day; and yet, so rapid is the March of the Mind, it has already risen into a national institution, and rivals, in its universal application to all ranks and ages, and as a specific for all the ills that flesh is heir to, the glorious Magna Charta.”
—Lewis Carroll [Charles Lutwidge Dodgson] (18321898)