MIL-STD-810 - MIL-STD-810G, PartTwo - Laboratory Test Methods

Laboratory Test Methods

Part Two of MIL-STD-810G contains the environmental laboratory test methods to be applied using the test tailoring guidelines described in Part One of the document. With the exception of Test Method 528, these methods are not mandatory, but rather the appropriate method is selected and tailored to generate the most relevant test data possible. Each test method in Part Two contains some environmental data and references, and it identifies particular tailoring opportunities. Each test method supports the test engineer by describing preferred laboratory test facilities and methodologies. These environmental management and engineering processes can be of enormous value to generate confidence in the environmental worthiness and overall durability of equipment and material. Still, the user must recognize that there are limitations inherent in laboratory testing that make it imperative to use engineering judgment when extrapolating from laboratory results to results that may be obtained under actual service conditions. In many cases, real-world environmental stresses (singularly or in combination) cannot be duplicated practically or reliably in test laboratories. Therefore, users should not assume that a system or component that passes laboratory tests of this standard also would pass field/fleet verification trials.

Specific examples of Test Methods called out in MIL-STD-810G are listed below:

  • Test Method 500.5 Low Pressure (Altitude)
  • Test Method 501.5 High Temperature
  • Test Method 502.5 Low Temperature
  • Test Method 503.5 Temperature Shock
  • Test Method 504.1 Contamination by Fluids
  • Test Method 505.5 Solar Radiation (Sunshine)
  • Test Method 506.5 Rain
  • Test Method 507.5 Humidity
  • Test Method 508.6 Fungus
  • Test Method 509.5 Salt Fog
  • Test Method 510.5 Sand and Dust
  • Test Method 511.5 Explosive Atmosphere
  • Test Method 512.5 Immersion
  • Test Method 513.6 Acceleration
  • Test Method 514.6 Vibration
  • Test Method 515.6 Acoustic Noise
  • Test Method 516.6 Shock
  • Test Method 517.1 Pyroshock
  • Test Method 518.1 Acidic Atmosphere
  • Test Method 519.6 Gunfire Shock
  • Test Method 520.3 Temperature, Humidity, Vibration, and Altitude
  • Test Method 521.3 Icing/Freezing Rain
  • Test Method 522.1 Ballistic Shock
  • Test Method 523.3 Vibro-Acoustic/Temperature
  • Test Method 524 Freeze / Thaw
  • Test Method 525 Time Waveform Replication
  • Test Method 526 Rail Impact.
  • Test Method 527 Multi-Exciter
  • Test Method 528 Mechanical Vibrations of Shipboard Equipment (Type I – Environmental and Type II – Internally Excited)

Read more about this topic:  MIL-STD-810, MIL-STD-810G, PartTwo

Famous quotes containing the words laboratory, test and/or methods:

    We are able to find everything in our memory, which is like a dispensary or chemical laboratory in which chance steers our hand sometimes to a soothing drug and sometimes to a dangerous poison.
    Marcel Proust (1871–1922)

    Unless the people can choose their leaders and rulers, and can revoke their choice at intervals long enough to test their measures by results, the government will be a tyranny exercised in the interests of whatever classes or castes or mobs or cliques have this choice.
    George Bernard Shaw (1856–1950)

    Generalization, especially risky generalization, is one of the chief methods by which knowledge proceeds... Safe generalizations are usually rather boring. Delete that “usually rather.” Safe generalizations are quite boring.
    Joseph Epstein (b. 1937)