Y-axis: Signal Intensity
The y-axis of a mass spectrum represents signal intensity of the ions. When using counting detectors the intensity is often measured in counts per second (cps). When using analog detection electronics the intensity is typically measured in volts. In FTICR and Orbitraps the frequency domain signal (the y-axis) is related to the power (~amplitude squared) of the signal sine wave (often reduced to an rms power); however, the axis is usually not labeled as such for many reasons. In most forms of mass spectrometry, the intensity of ion current measured by the spectrometer does not accurately represent relative abundance, but correlates loosely with it. Therefore it is common to label the y-axis with "arbitrary units".
Read more about this topic: Mass Spectrum
Famous quotes containing the words signal and/or intensity:
“Certainly the effort to remain unchanged, young, when the body gives so impressive a signal of change as the menopause, is gallant; but it is a stupid, self-sacrificial gallantry, better befitting a boy of twenty than a woman of forty-five or fifty. Let the athletes die young and laurel-crowned. Let the soldiers earn the Purple Hearts. Let women die old, white-crowned, with human hearts.”
—Ursula K. Le Guin (b. 1929)
“As siblings we were inextricably bound, even though our connections were loose and frayed.... And each time we met, we discovered to our surprise and dismay how quickly the intensity of childhood feelings reappeared.... No matter how old we got or how often we tried to show another face, reality was filtered through yesterdays memories.”