Neutral Fusing
Another practice that was common (and even required) in some older K&T designs was the installation of separate fuses in both the hot wire and the neutral (return) wire of an electrical circuit. The failure of a neutral fuse would cut off power flow through the affected circuit, but the hot conductor could still remain hot relative to ground, an unexpected and potentially hazardous situation. Because of the presence of a neutral fuse, the neutral conductor could not be relied on to remain near ground potential, and could in fact be at full line potential instead (via transmission of voltage through a switched-on light bulb, for example).
Modern electrical codes generally do not require a neutral fuse. Instead, they explicitly forbid configurations that might break continuity of the neutral conductor, unless all associated hot conductors are also simultaneously disconnected (for example, with ganged or "tied" circuit breakers).
Read more about this topic: Knob And Tube Wiring
Famous quotes containing the word neutral:
“The seashore is a sort of neutral ground, a most advantageous point from which to contemplate this world. It is even a trivial place. The waves forever rolling to the land are too far-traveled and untamable to be familiar. Creeping along the endless beach amid the sun-squall and the foam, it occurs to us that we, too, are the product of sea-slime.”