Energy Savings
In typical modern U.S. residences, about one-third of the HVAC energy consumption is due to infiltration. Another third is to ground-contact, and the remainder is to heat losses and gains through windows, walls, and other thermal loads. As such, reducing infiltration can yield significant energy savings, with rapid payback. In cold climates, with a 15 MPH wind, residences often have air exchange rates of 1.0 to 1.5 ACHs, far in excess of the ventilation air needs and are thus called loose construction. It is very easy to reduce infiltration rates to less than 1.0 ACH. Smoke candles and blower-door tests can help identify less-than-obvious leaks. The Weatherization article describes methods for energy savings further. If infiltration is reduced below 0.35 ACH, it is recommended that mechanical ventilation (typically an exhaust fan or heat recovery ventilation) be implemented.
Read more about this topic: Infiltration (HVAC)
Famous quotes containing the word energy:
“A government deriving its energy from the will of the society, and operating, by the reason of its measures, on the understanding and interest of the society ... is the government for which philosophy has been searching and humanity been fighting from the most remote ages ... which it is the glory of America to have invented, and her unrivalled happiness to possess.”
—James Madison (17511836)