IBM 729 - Data Format

Data Format

The tape had seven parallel tracks, six for data and one to maintain parity. Tapes with character data (BCD) were recorded in even parity. Binary tapes used odd parity. (709 manual p. 20) Aluminum strips were glued several feet from the ends of the tape to serve as logical beginning and end of tape markers. Write protection was provided by a removable plastic ring in the back of the tape reel. A 3/4 inch gap between records allowed the mechanism enough time to stop the tape. Initial tape speed was 75 inches per second (2.95 m/s) and recording density was 200 characters per inch, giving a transfer speed of 120 kbit/s. Later 729 models supported 556 and 800 characters/inch (transfer speed 480 kbit/s). At 200 characters per inch, a single 2400 foot tape could store the equivalent of some 50,000 punched cards (about 4,000,000 six-bit bytes, or 3 MByte).

The 729 series was superseded by 9 track tape drives introduced with the IBM System/360.

Read more about this topic:  IBM 729

Famous quotes containing the word data:

    Mental health data from the 1950’s on middle-aged women showed them to be a particularly distressed group, vulnerable to depression and feelings of uselessness. This isn’t surprising. If society tells you that your main role is to be attractive to men and you are getting crow’s feet, and to be a mother to children and yours are leaving home, no wonder you are distressed.