Hydrogen Damage - Detection of Hydrogen Damage

Detection of Hydrogen Damage

There are various methods of adequately identifying and monitoring hydrogen damage, including ultrasonic echo attenuation method, amplitude-based backscatter, velocity ratio, creeping waves/time-of-flight measurement, pitch-catch mode shear wave velocity, advanced ultrasonic backscatter techniques (AUBT), time of flight diffraction (TOFD), thickness mapping and in-situ metallography – replicas. For hydrogen damage, the backscatter technique is used to detect affected areas in the material. To cross-check and confirm the findings of the backscatter measurement, the velocity ratio measurement technique is used. For the detection of micro and macro cracks, time of flight diffraction is a suitable method to use.

Read more about this topic:  Hydrogen Damage

Famous quotes containing the words hydrogen and/or damage:

    The pace of science forces the pace of technique. Theoretical physics forces atomic energy on us; the successful production of the fission bomb forces upon us the manufacture of the hydrogen bomb. We do not choose our problems, we do not choose our products; we are pushed, we are forced—by what? By a system which has no purpose and goal transcending it, and which makes man its appendix.