Dropping Point - ASTM Test Procedure

ASTM Test Procedure

The dropping point test procedures are given in ASTM standards D-566 and D-2265. The test apparatus consists of a grease cup with a small hole in the bottom, test tube, two thermometers, a container, stirring device if required and an electric heater. The inside surfaces of the grease cup are coated with the grease to be tested. A thermometer is inserted into the cup and held in place so that the thermometer does not touch the grease. This assembly is placed inside a test tube. The test tube is lowered into the container which is filled with oil in D-566 and has an aluminum block in D-2265. Another thermometer is inserted into the oil/block.

To execute a test, the oil/block is heated, while being stirred, at a rate of 8 °F (4.4 °C) to 12 °F (6.7 °C) per minute until the temperature is approximately 30 °F (16.7 °C) below the expected dropping point. The heat is reduced until the test tube temperature is 4 °F (2.2 °C) or less than the oil/block temperature. Once the temperature has stabilized the sample is inserted. The dropping point is the temperature recorded on the test tube thermometer, plus a correction factor for the oil/block temperature, when a drop of grease falls through the hole in the grease cup. If the drop trails a thread, the dropping temperature is the temperature at which the thread breaks. D-2265 explains that the dropping point is useful to assist in identifying the type of grease, and for establishing and maintaining benchmarks for quality control. It adds that the results are not sufficient to assess service performance because dropping point is a static test.

Read more about this topic:  Dropping Point

Famous quotes containing the word test:

    We do not quite say that the new is more valuable because it fits in; but its fitting in is a test of its value—a test, it is true, which can only be slowly and cautiously applied, for we are none of us infallible judges of conformity.
    —T.S. (Thomas Stearns)