Class-D Amplifier - Error Control

Error Control

The actual output of the amplifier is not just dependent on the content of the modulated PWM signal. The power supply voltage directly amplitude-modulates the output voltage, dead time errors make the output impedance non-linear and the output filter has a strongly load-dependent frequency response. An effective way to combat errors, regardless of their source, is negative feedback. A feedback loop including the output stage can be made using a simple integrator. To include the output filter, a PID controller is used, sometimes with additional integrating terms. The need to feed the actual output signal back into the modulator makes the direct generation of PWM from a SPDIF source unattractive. Mitigating the same issues in an amplifier without feedback requires addressing each separately at the source. Power supply modulation can be partially canceled by measuring the supply voltage to adjust signal gain before calculating the PWM and distortion can be reduced by switching faster. The output impedance cannot be controlled other than through feedback.

Read more about this topic:  Class-D Amplifier

Famous quotes containing the words error and/or control:

    It is an old error of man to forget to put quotation marks where he borrows from a woman’s brain!
    Anna Garlin Spencer (1851–1931)

    We as a nation need to be reeducated about the necessary and sufficient conditions for making human beings human. We need to be reeducated not as parents—but as workers, neighbors, and friends; and as members of the organizations, committees, boards—and, especially, the informal networks that control our social institutions and thereby determine the conditions of life for our families and their children.
    Urie Bronfenbrenner (b. 1917)