Capacitor Plague - Electrolytic Capacitor Failures After 2007

Electrolytic Capacitor Failures After 2007

SEM image and EDX fingerprint analysis
Surface of "fresh" anode from a 1000 uF/10 V electrolytic capacitor; the pore openings in the anode are clearly visible, the surface is covered with aluminum oxide.
Surface of anode from a failed 1000 uF/10 V electrolytic capacitor; aluminum hydroxide has overgrown all structures on the anode. Failure occurred at the end of the calculated life span.

Read more about this topic:  Capacitor Plague

Famous quotes containing the word failures:

    I have never worked for fame or praise, and shall not feel their loss as I otherwise would. I have never for a moment lost sight of the humble life I was born to, its small environments, and the consequently little right I had to expect much of myself, and shall have the less to censure, or upbraid myself with for the failures I must see myself make.