Electrorheological Fluid - The ER Effect

The ER Effect

The change in apparent viscosity is dependent on the applied electric field, i.e. the potential divided by the distance between the plates. The change is not a simple change in viscosity, hence these fluids are now known as ER fluids, rather than by the older term Electro Viscous fluids. The effect is better described as an electric field dependent shear yield stress. When activated an ER fluid behaves as a Bingham plastic (a type of viscoelastic material), with a yield point which is determined by the electric field strength. After the yield point is reached, the fluid shears as a fluid, i.e. the incremental shear stress is proportional to the rate of shear (in a Newtonian fluid there is no yield point and stress is directly proportional to shear). Hence the resistance to motion of the fluid can be controlled by adjusting the applied electric field.

Read more about this topic:  Electrorheological Fluid

Famous quotes containing the word effect:

    We all have—to put it as nicely as I can—our lower centres and our higher centres. Our lower centres act: they act with terrible power that sometimes destroys us; but they don’t talk.... Since the war the lower centres have become vocal. And the effect is that of an earthquake. For they speak truths that have never been spoken before—truths that the makers of our domestic institutions have tried to ignore.