Central Venous Catheter - Insertion

Insertion

The skin is cleaned, and local anesthetic applied if required. The location of the vein is then identified by landmarks or with the use of a small ultrasound device. A hollow needle is advanced through the skin until blood is aspirated; the color of the blood and the rate of its flow help distinguish it from arterial blood (suggesting that an artery has been accidentally punctured), although this method is inaccurate. Ultrasound probably now represents the gold standard for central venous access and skills, within North American and Europe, with landmark techniques are diminishing.

The line is then inserted using the Seldinger technique: a blunt guidewire is passed through the needle, then the needle is removed. A dilating device may be passed over the guidewire to slightly enlarge the tract. Finally, the central line itself is then passed over the guidewire, which is then removed. All the lumens of the line are aspirated (to ensure that they are all positioned inside the vein) and flushed. A chest X-ray is typically performed afterwards to confirm that the line is positioned inside the superior vena cava and, in the case of insertion through the subclavian vein, that no pneumothorax was caused as a side effect. Vascular positioning systems can also be used to verify tip placement during insertion without the need to a chest X-ray, but this technique is not yet a standard of practice.

Videos are available demonstrating placement of a central venous catheter without and with ultrasound guidance.

Read more about this topic:  Central Venous Catheter

Other articles related to "insertion":

Adaptive Sort - Examples
... A classic example of an adaptive sorting algorithm is Straight Insertion Sort ... In pseudo-code form, the Straight Insertion Sort algorithm could look something like this procedure Straight Insertion Sort (X, n) X = − ∞ for j = 2 to n do begin i = j − 1 t = X while t < X do begin X ... – being relative to the number of inversions – Straight Insertion Sort takes less time to sort the closer it is to being sorted ...
Constant Voltage Speaker System - Disadvantages
... Insertion loss The transformers themselves commonly reduce total power applied to the loudspeakers, requiring the amplifier to be some ten to twenty percent more powerful ... Typical transformer insertion loss measurements are taken at 1,000 Hz in order to make the transformer's specifications appear as good as possible ... Using this method, typical insertion losses are about 1 dB, a 20% power loss ...
Migratory Insertion - Overview
... See also Ligand#Classification of ligands as L and X In the migratory insertion, a ligand that is viewed as an anion (X) ligand in and a ligand that is viewed as neutral couple ... If the precursor complex is coordinatively saturated, migratory insertion often result in the a coordinatively unsaturated product ... A new (neutral) ligand can then react with the metal leading to a further insertion ...
Migratory Insertion - CO Insertion - Mechanism
... into a metal-alkyl bond via migratory insertion ... to the migration, the metal binds free CO (see figure below) CO insertion does not always involve migration ... migration products and products formed by true insertion of bound carbonyls into the methyl group ...
Social Protection In France - History - Recent Evolution
... the CREDOC, a third of people between 25 and 59 had difficulty of insertion (unemployment during more than a year, beneficiaries of minimum social assistance or helped contract) ... President Nicolas Sarkozy announced the organization of a Grenelle Insertion dedicated to the transformation of integration policies ... Dedicated to return to work, the Grenelle insertion was concluded on 27 May 2008 ...