Bioelectrical Impedance Analysis

Bioelectrical impedance analysis (BIA) is a commonly used method for estimating body composition, and in particular body fat. Since the advent of the first commercially available devices in the mid-1980s the method has become popular owing to its ease of use, portability of the equipment and its relatively low cost compared to some of the other methods of body composition analysis. It is familiar in the consumer market as a simple instrument for estimating body fat. BIA actually determines the electrical impedance, or opposition to the flow of an electric current through body tissues which can then be used to calculate an estimate of total body water (TBW). TBW can be used to estimate fat-free body mass and, by difference with body weight, body fat.

Many of the early research studies showed that BIA was quite variable and it was not regarded by many as providing an accurate measure of body composition. In recent years technological improvements have made BIA a more reliable and therefore more acceptable way of measuring body composition. Nevertheless it is not a "gold standard" or reference method. Like all assessment tools, the result is only as good as the test done. Although the instruments are straightforward to use, careful attention to the method of use (as described by the manufacturer) should be given.

Simple devices to estimate body fat, often using BIA, are available to consumers as body fat meters. These instruments are generally regarded as being less accurate than those used clinically or in nutritional and medical practice. They tend to under-read body fat percentage.

In recent years, more accurate methods of Bioelectrical Impedance Analysis have been developed.

Read more about Bioelectrical Impedance AnalysisHistorical Background, Phase Angle

Other articles related to "bioelectrical impedance analysis":

Bodyfat - Measurement Techniques - Bioelectrical Impedance Analysis
... The bioelectrical impedance analysis (BIA) method is a lower-cost (from less than one to several hundred US dollars in 2006) but less accurate way to ...
Bioelectrical Impedance Analysis - Phase Angle
... In order to be able to differentiate between the two components resistance and reactance from the measured total resistance, modern BIA devices have phase sensitive electronics ... The principle of measurement is based upon the fact that the condensers in the alternating current circuit lead to a time delay Δt the current maximum is in advance of the voltage maximum ...