Activated Sludge - Activated Sludge Control

Activated Sludge Control

The general method to do this is to monitor sludge blanket level, SVI (Sludge Volume Index), MCRT (Mean Cell Residence Time), F/M (Food to Microorganism), as well as the biota of the activated sludge and the major nutrients DO (Dissolved oxygen), nitrogen, phosphate, BOD (Biological oxygen demand), and COD (Chemical oxygen demand).

In the reactor/aerator + clarifier system:

  • The sludge blanket is measured from the bottom of the clarifier to the level of settled solids in the clarifier's water column; this, in large plants, can be done up to three times a day.
  • The SVI is the volume of settled sludge in milliliters occupied by 1 gram of dry sludge solids after 30 minutes of settling in a 1000 milliliter graduated cylinder.
  • The MCRT is the total mass (lbs) of mixed liquor suspended solids in the aerator and clarifier divided by the mass flow rate (lbs/day) of mixed liquor suspended solids leaving as WAS and final effluent.
  • The F/M is the ratio of food fed to the microorganisms each day to the mass of microorganisms held under aeration. Specifically, it is the amount of BOD fed to the aerator (lbs/day) divided by the amount (lbs) of MLVSS (Mixed Liquor Volatile Suspended Solids) under aeration. Note: Some references use MLSS (Mixed Liquor Suspended Solids) for expedience, but MLVSS is considered more accurate for the measure of microorganisms. Again, due to expedience, COD is generally used, in lieu of BOD, as BOD takes five days for results.

Read more about this topic:  Activated Sludge

Famous quotes containing the word control:

    Imagine believing in the control of inflation by curbing the money supply! That is like deciding to stop your dog fouling the sidewalk by plugging up its rear end. It is highly unlikely to succeed, but if it does it kills the hound.
    —Michael D. Stephens. “On Sinai, There’s No Economics,” New York Times (Nov. 13, 1981)