Unibus - History

History

The Unibus was developed around 1969 by Gordon Bell and student Harold McFarland while at Carnegie Mellon University.

The Unibus was composed of 72 wires (2 connectors x 36 lines per connector). When not counting the power and ground lines, it is usually referred to as a 56 line bus. It could exist within a backplane or on a cable. Up to 20 nodes (devices) could be connected to a single Unibus segment; additional segments could be connected via a bus repeater.

The bus was completely asynchronous, allowing a mixture of fast and slow devices. It allowed the overlapping of arbitration (selection of the next bus master) while the current bus master was still performing data transfers. The 18 address lines allowed the addressing of a maximum of 256 kB. Typically, the top 8 kB was reserved for the registers of the memory-mapped I/O devices used in the PDP-11 architecture.

The design deliberately minimized the amount of redundant logic required in the system. For example, a system always contained more slave devices than master devices so most of the fancy logic required to implement asynchronous data transfers was forced into the relatively few master devices. For interrupts, only the interrupt-fielding processor needed to contain the complicated timing logic. The end result was that most I/O controllers could be implemented with very simple logic and most of the critical logic was implemented as a custom MSI IC.

18 A00-A17 - Address Lines 16 D00-D15 - Data Lines 4 BR4-BR7 - Bus (Interrupt) Requests at priorities 4 (lowest) through 7 (highest) 4 BG4-BG7 - Bus (Interrupt) Grants at priorities 4 (lowest) through 7 (highest) 1 NPR - Non Processor (DMA) Request 1 NPG - Non Processor (DMA) Grant 1 ACLO - AC Low 1 DCLO - DC Low 1 MSYNC - Master Sync 1 SSYNC - Slave Sync 1 BBSY - Bus Busy 1 SACK - Selection Acknowledge 1 INIT - Bus Init 1 INTR - Interrupt Request 1 PA - Parity control 1 PB - Parity control 2 C0-C1 - Cyce Control Lines: 2 +5v - Power Lines (not counted as part of the 56) 14 Gnd - Ground Lines (not counted as part of the 56)

The two control lines (C0 and C1) allowed the selection of four different data transfer cycles:

  • DATI (Data In, a read)
  • DATIP (Data In/Pause, the first portion of a Read-Modify-Write operation. A DATO or DATOB operation completes this.)
  • DATO (Data Out, a word write)
  • DATOB (Data Out/Byte, a byte write)
  • During an interrupt cycle, a fifth style of transfer was automatically invoked to convey an interrupt vector from the interrupting device to the interrupt-fielding processor.

Read more about this topic:  Unibus

Famous quotes containing the word history:

    the future is simply nothing at all. Nothing has happened to the present by becoming past except that fresh slices of existence have been added to the total history of the world. The past is thus as real as the present.
    Charlie Dunbar Broad (1887–1971)