The safety curtain can be combined with other safety devices, such as:

  • Smoke pockets - are steel channels located at either side of the proscenium arch that the safety curtain travels within to create a physical barrier between the auditorium and the stage. The safety curtain is not intended to create an air seal but rather prevent material from falling from the stage house into the audience.
  • Fire doors - heavy, fireproof doors that are designed to automatically close any doorway onto the stage in the event of a fire. These doors are usually on a slightly pitched track, and are rigged in a way that causes them to automatically close when heated to a certain temperature.
  • Smoke doors or stage lantern - vents above the stage which, when opened in case of fire, will draw smoke out of the auditorium and up out of the roof of the theatre, enabling safer evacuation of the audience. The vents are often attached to compressed springs, so that when activated, they will stay open.
  • Drencher or deluge system - a large reservoir of water stored above the stage which, when released in case of fire, will flood the stage in an attempt to extinguish any flames. This type of system can be problematic, as water interacting with onstage electrical circuits can cause fire.
  • Water Curtain- a system similar to the deluge system, except instead of having the water drench the stage itself, the water flows from sprinkler heads or other nozzles directly in front of the proscenium to prevent sparks from flying off the stage or to extinguish any burning material (such as a set) which may fall through the proscenium.

In the event of a fire, the use of smoke doors and fire curtains means that the stage area effectively functions as a chimney. The heated air rises and leaves through the smoke doors, and this puts the building into negative pressure, which in turn draws fresh air in through any open exit doors. Patrons waiting to exit will have fresh breathing air until the exit doors close. The exit doors which open out will be drawn closed tightly by this draft once they are no longer held open by evacuees. Once the doors are closed, the fire loses its oxygen source. If the doors are then opened again, a backdraft can occur.

Read more about this topic:  Safety Curtain

Famous quotes containing the words related, stage, fire, safety and/or devices:

    Generally there is no consistent evidence of significant differences in school achievement between children of working and nonworking mothers, but differences that do appear are often related to maternal satisfaction with her chosen role, and the quality of substitute care.
    Ruth E. Zambrana, U.S. researcher, M. Hurst, and R.L. Hite. “The Working Mother in Contemporary Perspectives: A Review of Literature,” Pediatrics (December 1979)

    She does not realize that the only difference between us is that she is on one stage and I on another. I feel that I am acting just as much as she is.
    William Howard Taft (1857–1930)

    Perhaps my best years are gone. When there was a chance of happiness. But I wouldn’t want them back. Not with the fire in me now.
    Samuel Beckett (1906–1989)

    Firm, united, let us be,
    Rallying round our Liberty;
    As a band of brothers joined,
    Peace and safety we shall find.
    Joseph Hopkinson (1770–1842)

    So that with much ado I was corrupted, and made to learn the dirty devices of this world.
    Which now I unlearn, and become, as it were, a little child again that I may enter into the Kingdom of God.
    Thomas Traherne (1636–1674)