Typical Per-unit-thickness R-values For Material
Material | m2·K/(W·in) | ft2·°F·h/(BTU·in) | m·K/W |
---|---|---|---|
Vacuum insulated panel | 7.04 !5.28–8.8 | 3000 !R-30–R-50 | |
Silica aerogel | 1.76 !1.76 | 1000 !R-10 | |
Polyurethane rigid panel (CFC/HCFC expanded) initial | 1.32 !1.23–1.41 | 0700 !R-7–R-8 | |
Polyurethane rigid panel (CFC/HCFC expanded) aged 5–10 years | 1.1 !1.10 | 0625 !R-6.25 | |
Polyurethane rigid panel (pentane expanded) initial | 1.2 !1.20 | 0680 !R-6.8 | |
Polyurethane rigid panel (pentane expanded) aged 5–10 years | 0.97 !0.97 | 0550 !R-5.5 | |
Foil faced Polyurethane rigid panel (pentane expanded) | 45-48 | ||
Foil-faced polyisocyanurate rigid panel (pentane expanded ) initial | 1.2 !1.20 | 0680 !R-6.8 | 55 |
Foil-faced polyisocyanurate rigid panel (pentane expanded) aged 5–10 years | 0.97 !0.97 | 0550 !R-5.5 | |
Polyisocyanurate spray foam | 1.11 !0.76–1.46 | 0430 !R-4.3–R-8.3 | |
Closed-cell polyurethane spray foam | 1.055 !0.97–1.14 | 0550 !R-5.5–R-6.5 | |
Phenolic spray foam | 1.04 !0.85–1.23 | 0480 !R-4.8–R-7 | |
Thinsulate clothing insulation | 1.01 !1.01 | 0575 !R-5.75 | |
Urea-formaldehyde panels | 0.97 !0.88–1.06 | 0500 !R-5–R-6 | |
Urea foam | 0.924 !0.92 | 0525 !R-5.25 | |
Extruded expanded polystyrene (XPS) high-density | 0.915 !0.88–0.95 | 0500 !R-5–R-5.4 | 26-40 |
Polystyrene board | 0.88 !0.88 | 0500 !R-5.00 | |
Phenolic rigid panel | 0.79 !0.70–0.88 | 0400 !R-4–R-5 | |
Urea-formaldehyde foam | 0.755 !0.70–0.81 | 0400 !R-4–R-4.6 | |
High-density fiberglass batts | 0.755 !0.63–0.88 | 0360 !R-3.6–R-5 | |
Extruded expanded polystyrene (XPS) low-density | 0.725 !0.63–0.82 | 0360 !R-3.6–R-4.7 | |
Icynene loose-fill (pour fill) | 0.7 !0.70 | 0400 !R-4 | |
Molded expanded polystyrene (EPS) high-density | 0.7 !0.70 | 0400 !R-4.2 | 22-32 |
Air-entrained concrete | 0.686 !0.69 | 0390 !R-3.90 | |
Home Foam | 0.686 !0.69 | 0390 !R-3.9 | |
Fiberglass batts | 0.655 !0.55–0.76 | 0310 !R-3.1–R-4.3 | |
Cotton batts (Blue Jean insulation) | 0.65 !0.65 | 0370 !R-3.7 | |
Molded expanded polystyrene (EPS) low-density | 0.65 !0.65 | 0370 !R-3.85 | |
Icynene spray | 0.63 !0.63 | 0360 !R-3.6 | |
Open-cell polyurethane spray foam | 0.63 !0.63 | 0360 !R-3.6 | |
Cardboard | 0.61 !0.52–0.7 | 0300 !R-3–R-4 | |
Rock and slag wool batts | 0.6 !0.52–0.68 | 0300 !R-3–R-3.85 | |
Cellulose loose-fill | 0.595 !0.52–0.67 | 0300 !R-3–R-3.8 | |
Cellulose wet-spray | 0.595 !0.52–0.67 | 0300 !R-3–R-3.8 | |
Rock and slag wool loose-fill | 0.545 !0.44–0.65 | 0250 !R-2.5–R-3.7 | |
Fiberglass loose-fill | 0.545 !0.44–0.65 | 0250 !R-2.5–R-3.7 | |
Polyethylene foam | 0.52 !0.52 | 0300 !R-3 | |
Cementitious foam | 0.52 !0.35–0.69 | 0200 !R-2–R-3.9 | |
Perlite loose-fill | 0.48 !0.48 | 0270 !R-2.7 | |
Wood panels, such as sheathing | 0.44 !0.44 | 0250 !R-2.5 | 9 |
Fiberglass rigid panel | 0.44 !0.44 | 0250 !R-2.5 | |
Vermiculite loose-fill | 0.4 !0.38–0.42 | 0213 !R-2.13–R-2.4 | |
Vermiculite | 0.375 !0.38 | 0213 !R-2.13 | 16-17 |
Straw bale | 0.26 !0.26 | 0145 !R-1.45 | 16-22 |
Papercrete | 0260 !R-2.6-R-3.2 | ||
Softwood (most) | 0.25 !0.25 | 0141 !R-1.41 | 7.7 |
Wood chips and other loose-fill wood products | 0.18 !0.18 | 0100 !R-1 | |
Snow | 0.18 !0.18 | 0100 !R-1 | |
Hardwood (most) | 0.12 !0.12 | 0071 !R-0.71 | 5.5 |
Brick | 0.03 !0.030 | 0020 !R-0.2 | 1.3-1.8 |
Glass | 0.024 !0.025 | 0024 !R-0.14 | |
Poured concrete | 0.014 !0.014 | 0008 !R-0.08 | 0.43-0.87 |
Read more about this topic: R-value (insulation), Example Values
Famous quotes containing the words typical and/or material:
“It was announced that the trouble was not malignant.... It was a typical triumph of modern science to find the only part of Randolph that was not malignant and remove it.”
—Evelyn Waugh (19031966)
“Our theism is the purification of the human mind. Man can paint, or make, or think nothing but man. He believes that the great material elements had their origin from his thought.”
—Ralph Waldo Emerson (18031882)