Based on the NPS and schedule of a pipe, the pipe outside diameter (OD) and wall thickness can be obtained from reference tables such as those below, which are based on ASME standards B36.10M and B36.19M. For example, NPS 14 Sch 40 has an OD of 14 inches and a wall thickness of 0.437 inches. However the NPS and OD values are not always equal, which can create confusion.

  • For NPS ⅛ to 12 inches, the NPS and OD values are different. For example, the OD of an NPS 12 pipe is actually 12.75 inches. To find the actual OD for each NPS value, refer to the tables below. (Note that for tubing, the size is always the actual OD.)
  • For NPS 14 inches and up, the NPS and OD values are equal. In other words, an NPS 14 pipe is actually 14 inches OD.

The reason for the discrepancy for NPS ⅛ to 12 inches is that these NPS values were originally set to give the same inside diameter (ID) based on wall thicknesses standard at the time. However, as the set of available wall thicknesses evolved, the ID changed and NPS became only indirectly related to ID and OD.

For a given NPS, the OD stays fixed and the wall thickness increases with schedule. For a given schedule, the OD increases with NPS while the wall thickness stays constant or increases. Using equations and rules in ASME B31.3 Process Piping, it can be shown that pressure rating decreases with increasing NPS and constant schedule.

Some specifications use pipe schedules called standard wall (STD), extra strong (XS), and double extra strong (XXS), although these actually belong to an older system called iron pipe size (IPS). The IPS number is the same as the NPS number. STD is identical to SCH 40S, and 40S is identical to 40 for NPS 1/8 to NPS 10, inclusive. XS is identical to SCH 80S, and 80S is identical to 80 for NPS 1/8 to NPS 8, inclusive. XXS wall is thicker than schedule 160 from NPS 1/8" to NPS 6" inclusive, and schedule 160 is thicker than XXS wall for NPS 8" and larger.

Blockage or Ball Test: When a pipe is welded or bent the most common method to inspect blockages, misalignment, ovality, and weld bead dimensional conformity is to pass a round ball through the pipe coil or circuit. The inner pipe dimension must be measured then you should subtract the weld bead if welding is applicable, usually the tolerance for dimensional clearance for the ball must not exceed 1mm. Allowable ovality of any pipe is measured to the inside dimension of the pipe, normally 5% to 10% ovality can be accepted. If no other test is conducted to verify ovality or blockages this test must be seen as a standard requirement. Also note that a flow test can not be used to replace a Blockage or Ball Test. See pipe dimensional table, Specification ASME B36.10M or B36.19M for pipe dimensions per schedule.

The "S" designation, for example "NPS Sch 10S", most often indicates stainless steel pipes. However some stainless steel pipes are available in steel designations, so strictly speaking the "S" designation only differentiates B36.19M pipe from B36.10M pipe.

Both polyvinyl chloride pipe (PVC) and chlorinated polyvinyl chloride pipe (CPVC) are made in NPS sizes.

Read more about this topic:  Nominal Pipe Size

Famous quotes containing the word application:

    If you would be a favourite of your king, address yourself to his weaknesses. An application to his reason will seldom prove very successful.
    Philip Dormer Stanhope, 4th Earl Chesterfield (1694–1773)

    “Five o’clock tea” is a phrase our “rude forefathers,” even of the last generation, would scarcely have understood, so completely is it a thing of to-day; and yet, so rapid is the March of the Mind, it has already risen into a national institution, and rivals, in its universal application to all ranks and ages, and as a specific for “all the ills that flesh is heir to,” the glorious Magna Charta.
    Lewis Carroll [Charles Lutwidge Dodgson] (1832–1898)

    The application requisite to the duties of the office I hold [governor of Virginia] is so excessive, and the execution of them after all so imperfect, that I have determined to retire from it at the close of the present campaign.
    Thomas Jefferson (1743–1826)