The SES-2 command set uses the SCSI SEND DIAGNOSTIC and RECEIVE DIAGNOSTIC RESULTS commands to obtain configuration information for the enclosure and to set and sense standard bits for each element installed in the enclosure. The SEND DIAGNOSTIC command is used to send control information to internal or external LED indicators or to instruct one enclosure element to change its state or perform an operation. Access to the e The application client has two mechanisms for accessing the enclosure service process:

a) Directly to a standalone enclosure services process, for example an enclosure controller chip. SCSI conditions communicated directly include hard reset, logical unit Reset and I_T nexus loss.
b) Indirectly through a LUN of another peripheral device – for example a drive within the enclosure. The drive will communicate with the Enclosure Through the Enclosure Services Interface. In this case the only SCSI device condition communicated through the LUN is hard reset.

Read more about this topic:  SES-2 Enclosure Management

Famous quotes containing the word commands:

    The power of a text is different when it is read from when it is copied out.... Only the copied text thus commands the soul of him who is occupied with it, whereas the mere reader never discovers the new aspects of his inner self that are opened by the text, that road cut through the interior jungle forever closing behind it: because the reader follows the movement of his mind in the free flight of day-dreaming, whereas the copier submits it to command.