Serial Vector Format - SVF Commands

SVF Commands

  • ENDDR: Specifies default end state for DR scan operations.
  • ENDIR: Specifies default end state for IR scan operations.
  • FREQUENCY: Specifies maximum test clock frequency for IEEE 1149.1 bus operations.
  • HDR: (Header Data Register) Specifies a header pattern that is prepended to the beginning of subsequent DR scan operations.
  • HIR: (Header Instruction Register) Specifies a header pattern that is prepended to the beginning of subsequent IR scan operations.
  • PIO: (Parallel Input/Output) Specifies a parallel test pattern.
  • PIOMAP: (Parallel Input/Output Map) Maps PIO column positions to a logical pin.
  • RUNTEST: Forces the IEEE 1149.1 bus to a run state for a specified number of clocks or a specified time period.
  • SDR: (Scan Data Register) Performs an IEEE 1149.1 Data Register scan.
  • SIR: (Scan Instruction Register) Performs an IEEE 1149.1 Instruction Register scan.
  • STATE: Forces the IEEE 1149.1 bus to a specified stable state.
  • TDR: (Trailer Data Register) Specifies a trailer pattern that is appended to the end of subsequent DR scan operations.
  • TIR: (Trailer Instruction Register) Specifies a trailer pattern that is appended to the end of subsequent IR scan operations.
  • TRST: (Test ReSeT) Controls the optional Test Reset line.

Read more about this topic:  Serial Vector Format

Famous quotes containing the word commands:

    They went to him and woke him up, shouting, “Master, Master, we are perishing!” And he woke up and rebuked the wind and the raging waves; they ceased, and there was a calm. He said to them, “Where is your faith?” They were afraid and amazed, and said to one another, “Who then is this, that he commands even the winds and the water, and they obey him?”