Related Stage Fire Safety Devices
The safety curtain can be combined with other safety devices, such as:
- Smoke pockets - are steel channels located at either side of the proscenium arch that the safety curtain travels within to create a physical barrier between the auditorium and the stage. The safety curtain is not intended to create an air seal but rather prevent material from falling from the stage house into the audience.
- Fire doors - heavy, fireproof doors that are designed to automatically close any doorway onto the stage in the event of a fire. These doors are usually on a slightly pitched track, and are rigged in a way that causes them to automatically close when heated to a certain temperature.
- Smoke doors or stage lantern - vents above the stage which, when opened in case of fire, will draw smoke out of the auditorium and up out of the roof of the theatre, enabling safer evacuation of the audience. The vents are often attached to compressed springs, so that when activated, they will stay open.
- Drencher or deluge system - a large reservoir of water stored above the stage which, when released in case of fire, will flood the stage in an attempt to extinguish any flames. This type of system can be problematic, as water interacting with onstage electrical circuits can cause fire.
- Water Curtain- a system similar to the deluge system, except instead of having the water drench the stage itself, the water flows from sprinkler heads or other nozzles directly in front of the proscenium to prevent sparks from flying off the stage or to extinguish any burning material (such as a set) which may fall through the proscenium.
In the event of a fire, the use of smoke doors and fire curtains means that the stage area effectively functions as a chimney. The heated air rises and leaves through the smoke doors, and this puts the building into negative pressure, which in turn draws fresh air in through any open exit doors. Patrons waiting to exit will have fresh breathing air until the exit doors close. The exit doors which open out will be drawn closed tightly by this draft once they are no longer held open by evacuees. Once the doors are closed, the fire loses its oxygen source. If the doors are then opened again, a backdraft can occur.
Read more about this topic: Safety Curtain
Famous quotes containing the words related, stage, fire, safety and/or devices:
“The near explains the far. The drop is a small ocean. A man is related to all nature. This perception of the worth of the vulgar is fruitful in discoveries. Goethe, in this very thing the most modern of the moderns, has shown us, as none ever did, the genius of the ancients.”
—Ralph Waldo Emerson (18031882)
“We must be willing to change chairs if we want to grow. There is no permanent compatibility between a chair and a person. And there is no one right chair. What is right at one stage may be restricting at another or too soft. During the passage from one stage to another, we will be between two chairs. Wobbling no doubt, but developing.”
—Gail Sheehy (20th century)
“Men hold themselves cheap and vile; and yet a man is a fagot of thunderbolts. All the elements pour through his system: he is the flood of the flood, and fire of the fire; he feels the antipodes and the pole, as drops of his blood: they are the extension of his personality.”
—Ralph Waldo Emerson (18031882)
“Love no man in good earnest, nor no further in sport
neither, than with safety of a pure blush thou mayst in
honor come off again.”
—William Shakespeare (15641616)
“There is nothing in machinery, there is nothing in embankments and railways and iron bridges and engineering devices to oblige them to be ugly. Ugliness is the measure of imperfection.”
—H.G. (Herbert George)