Optical Fiber Connector - Analysis

Analysis

  • FC connectors' floating ferrule provides good mechanical isolation. FC connectors need to be mated more carefully than the push-pull types due to the need to align the key, and due to the risk of scratching the fiber end face while inserting the ferrule into the jack. FC connectors have been replaced in many applications by SC and LC connectors.
  • There are two incompatible standards for key widths on FC/APC and polarization-maintaining FC/PC connectors: 2 mm ("Reduced" or "type R") and 2.14 mm ("NTT" or "type N"). Connectors and receptacles with different key widths either cannot be mated, or will not preserve the angle alignment between the fibers, which is especially important for polarization-maintaining fiber. Some manufacturers mark reduced keys with a single scribe mark on the key, and mark NTT connectors with a double scribe mark.
  • SC connectors offer excellent packing density, and their push-pull design reduces the chance of fiber end face contact damage during connection; frequently found on the previous generation of corporate networking gear, using GBICs.
  • LC connectors have replaced SC connectors in corporate networking environments due to their smaller size; they are often found on small form-factor pluggable transceivers.
  • ST connectors have a key which prevents rotation of the ceramic ferrule, and a bayonet lock similar to a BNC shell. The single index tab must be properly aligned with a slot on the mating receptacle before insertion; then the bayonet interlock can be engaged, by pushing and twisting, locking at the end of travel which maintains spring-loaded engagement force on the core optical junction.
  • In general the insertion loss should not exceed 0.75 dB and the return loss should be higher than 20 dB. Typical insertion repeatability, the difference in insertion loss between one plugging and another, is 0.2 dB.
  • On all connectors, cleaning the ceramic ferrule before each connection helps prevent scratches and extends the connector life substantially.
  • Connectors on polarization-maintaining fiber are sometimes marked with a blue strain relief boot or connector body, although this is far from a universal standard. Sometimes a blue buffer tube is used on the fiber instead.
  • MT-RJ (Mechanical Transfer Registered Jack) uses a form factor and latch similar to the 8P8C (RJ45) connectors. Two separate fibers are included in one unified connector. It is easier to terminate and install than ST or SC connectors. The smaller size allows twice the port density on a face plate than ST or SC connectors do. The MT-RJ connector was designed by AMP, but was later standardized as FOCIS 12 (Fiber Optic Connector Intermateability Standards) in EIA/TIA-604-12. There are two variations: pinned and no-pin. The pinned variety, which has two small stainless steel guide pins on the face of the connector, is used in patch panels to mate with the no-pin connectors on MT-RJ patch cords.
  • Hardened Fiber Optic Connectors (HFOCs) and Hardened Fiber Optic Adapters (HFOAs) are passive telecommunications components used in an Outside Plant (OSP) environment. They provide drop connections to customers from fiber distribution networks. These components may be provided in pedestal closures, aerial and buried closures and terminals, or equipment located at customer premises such as a Fiber Distribution Hub (FDH) or an Optical Network Terminal or Termination (ONT) unit.

These connectors, which are field-mateable, and hardened for use in the OSP, are needed to support Fiber to the Premises (FTTP) deployment and service offerings. HFOCs are designed to withstand climatic conditions existing throughout the U.S., including rain, flooding, snow, sleet, high winds, and ice and sand storms. Ambient temperatures ranging from –40°C (–40°F) to +70°C (158°F) can be encountered.

Telcordia contains the industry’s most recent requirements for HFOCs and HFOAs.

Read more about this topic:  Optical Fiber Connector

Famous quotes containing the word analysis:

    Analysis as an instrument of enlightenment and civilization is good, in so far as it shatters absurd convictions, acts as a solvent upon natural prejudices, and undermines authority; good, in other words, in that it sets free, refines, humanizes, makes slaves ripe for freedom. But it is bad, very bad, in so far as it stands in the way of action, cannot shape the vital forces, maims life at its roots. Analysis can be a very unappetizing affair, as much so as death.
    Thomas Mann (1875–1955)