Kedzierzyn Zero-Emission Plant - Technical Parameters

Technical Parameters

Parameters Units Zero-Emission Power &
Chemical Complex
Fuel consumption
power coal mio Mg/year 2.07
biomass mio Mg/year 0.23
Thermal power MWt 137
Electric Power MWe 309
Synthesis gas production: bn Nm3/year 1.55
equivalent methanol quantity Mg/year 550
Captured CO2 mio Mg/year 3.38
neutralised (sequestrated) CO2 mio Mg/year 2.54
equivalent contained in synthesis gas for methanol mio Mg/year 0.84
CO2 emissions % 8x
Reduction of CO2 emissions % 92

x Introduction of biomass into the combustion process can result in negative total carbon emission

Read more about this topic:  Kedzierzyn Zero-Emission Plant

Famous quotes containing the words technical and/or parameters:

    I rather think the cinema will die. Look at the energy being exerted to revive it—yesterday it was color, today three dimensions. I don’t give it forty years more. Witness the decline of conversation. Only the Irish have remained incomparable conversationalists, maybe because technical progress has passed them by.