Fourier Transform Ion Cyclotron Resonance

Fourier Transform Ion Cyclotron Resonance

Fourier transform ion cyclotron resonance mass spectrometry, also known as Fourier transform mass spectrometry, is a type of mass analyzer (or mass spectrometer) for determining the mass-to-charge ratio (m/z) of ions based on the cyclotron frequency of the ions in a fixed magnetic field. The ions are trapped in a Penning trap (a magnetic field with electric trapping plates) where they are excited (at their resonant cyclotron frequencies) to a larger cyclotron radius by an oscillating electric field orthogonal to the magnetic field. After the excitation field is removed, the ions are rotating at their cyclotron frequency in phase (as a "packet" of ions). These ions induce a charge (detected as an image current) on a pair of electrodes as the packets of ions pass close to them. The resulting signal is called a free induction decay (FID), transient or interferogram that consists of a superposition of sine waves. The useful signal is extracted from this data by performing a Fourier transform to give a mass spectrum.

Fourier transform ion cyclotron resonance (FTICR) mass spectrometry is a very high resolution technique that can be used to determine masses with very high accuracy. Many applications of FTICR-MS use this mass accuracy to help determine the composition of molecules based on accurate mass. This is possible due to the mass defect of the elements. FTICR-MS is able to achieve higher levels of resolution than other forms of mass spectometer, in part, because a superconducting magnet is much more stable than RF (radio frequency) voltage. Another place that FTICR-MS is useful is in dealing with complex mixtures since the resolution (narrow peak width) allows the signals of two ions of similar mass to charge (m/z) to be detected as distinct ions. This high resolution is also useful in studying large macromolecules such as proteins with multiple charges which can be produced by electrospray ionization. For example, attomole level of detection of two peptides has been reported . These large molecules contain a distribution of isotopes that produce a series of isotopic peaks. Because the isotopic peaks are close to each other on the m/z axis, due to the multiple charges, the high resolving power of the FTICR is extremely useful.

FTICR-MS differs significantly from other mass spectrometry techniques in that the ions are not detected by hitting a detector such as an electron multiplier but only by passing near detection plates. Additionally the masses are not resolved in space or time as with other techniques but only by the cyclotron (rotational) frequency that each ion produces as it rotates in a magnetic field. Thus, the different ions are not detected in different places as with sector instruments or at different times as with time-of-flight instruments but all ions are detected simultaneously during the detection interval. This provides an increase in the observed signal to noise ratio owing to the principles of Fellgett's advantage. In FTICR-MS, resolution can be improved either by increasing the strength of the magnet (in teslas) or by increasing the detection duration.

Read more about Fourier Transform Ion Cyclotron Resonance:  History, Theory, ICR Cell Types, Stored Waveform Inverse Fourier Transform

Famous quotes containing the words transform and/or resonance:

    The lullaby is the spell whereby the mother attempts to transform herself back from an ogre to a saint.
    James Fenton (b. 1949)

    It is closing time in the gardens of the West and from now on an artist will be judged only by the resonance of his solitude or the quality of his despair.
    Cyril Connolly (1903–1974)