Reference Range
The upper normal level of eNO in different studies ranges from 20 to 30 parts per billion. However, several major features influence the reference values. Men have higher eNO values than women. Smoking notoriously lowers eNO values, and even former smoking status can influence results. The levels are higher in people with an atopic constitution (a tendency towards allergies). The fraction of eNO is also flow-dependent (higher at lower flow rates and vice versa), so measurements are normally measured at 50 ml/s. Age or height could also considerably confound eNO values in children. The magnitude of these effects lies in the order of 10%, so even single cut-off values might be useful.
Read more about this topic: Exhaled Nitric Oxide
Famous quotes containing the words reference and/or range:
“I think, for the rest of my life, I shall refrain from looking up things. It is the most ravenous time-snatcher I know. You pull one book from the shelf, which carries a hint or a reference that sends you posthaste to another book, and that to successive others. It is incredible, the number of books you hopefully open and disappointedly close, only to take down another with the same result.”
—Carolyn Wells (18621942)
“They didnt know
how
my heart woke
to a range and measure
of song
I hadnt known.”
—Hilda Doolittle (18861961)