Contact Breaker - Operation

Operation

The contact breaker is operated by an engine-driven cam, and the position of the contact breaker is set so that they open (and hence generate a spark) at the exactly correct moment needed to ignite the fuel at the top of the piston's compression stroke. The contact breaker is usually mounted on a plate that is able to rotate relative to the camshaft operating it. The plate is rotated by a centrifugal mechanism, thus advancing the ignition timing (making the spark occur earlier) at higher revolutions. This gives the fuel time to burn so that the resulting gases reach their maximum pressure at the same time as the piston reaches the top of the cylinder. The plate's position can also be moved a small distance using a small manifold vacuum-operated servomechanism, providing advanced timing when the engine is required to speed up on demand. This helps to prevent pre-ignition (or pinging).

Read more about this topic:  Contact Breaker

Famous quotes containing the word operation:

    It is critical vision alone which can mitigate the unimpeded operation of the automatic.
    Marshall McLuhan (1911–1980)

    It requires a surgical operation to get a joke well into a Scotch understanding. The only idea of wit, or rather that inferior variety of the electric talent which prevails occasionally in the North, and which, under the name of “Wut,” is so infinitely distressing to people of good taste, is laughing immoderately at stated intervals.