Computer Automated Measurement and Control

Computer Automated Measurement And Control (CAMAC) is a standard bus for Data acquisition and control used in nuclear and particle physics experiments and in industry. The bus allows data exchange between plug-in modules (up to 24 in a single crate) and a crate controller, which then interfaces to PC or to a VME-CAMAC interface.

The standard was originally defined by the ESONE Committee as standard EUR 4100 in 1972, and covers the mechanical, electrical and logic of a parallel bus (dataway) for the plug-in modules. Several standards have been defined for multiple crate systems including the Parallel Branch Highway definition and Serial Highway definition. Vendor specific Host/Crate interfaces have also been built.

The CAMAC standard encompasses IEEE standards:

  • 583 The base standard
  • 683 Block transfer specifications (Q-stop and Q-scan)
  • 596 Parallel Branch Highway systems
  • 595 Serial highway system
  • 726 Real-time Basic for CAMAC
  • 675 Auxiliary crate controller specification/support
  • 758 FORTRAN subroutines for CAMAC.

Within the dataway, modules are addressed by slot (Geographical addressing). The left-most 22 slots are available for application modules while the right-most two slots are dedicated to a crate controller. Within a slot the standard defines 16 subaddresses (0–15). A slot commanded by the controller with one of 32 function codes (0–31). Of these function codes, 0–7 are read functions and will transfer data to the controller from the addressed module, while 16–23 are write function codes which will transfer data from the controller to the module.

In addition to functions that address the module, the following global functions are defined:

  • I – Crate inhibit
  • Z – Crate zero.
  • C – Crate clear.

The original standard was capable of one 24 bit data transfer every microsecond. Later a revision to the standard was released to support short cycles which allow a transfer every 450ns. A follow on upwardly compatible standard Fast CAMAC allows the crate cycle time to be tuned to the capabilities of the modules in each slot.

The FASTBUS standard was introduced in 1984 as a replacement for CAMAC in large systems.

Famous quotes containing the words computer, automated, measurement and/or control:

    Family life is not a computer program that runs on its own; it needs continual input from everyone.
    Neil Kurshan (20th century)

    Now, as always, the most automated appliance in a household is the mother.
    Beverly Jones (b. 1927)

    That’s the great danger of sectarian opinions, they always accept the formulas of past events as useful for the measurement of future events and they never are, if you have high standards of accuracy.
    John Dos Passos (1896–1970)

    America is neither free nor brave, but a land of tight, iron- clanking little wills, everybody trying to put it over everybody else, and a land of men absolutely devoid of the real courage of trust, trust in life’s sacred spontaneity. They can’t trust life until they can control it.
    —D.H. (David Herbert)