Maximum Length
When used for 10/100/1000BASE-T, the maximum allowed length of a Cat 6 cable is 100 meters or 328 feet. This consists of 90 meters (300 ft) of solid "horizontal" cabling between the patch panel and the wall jack, plus 10 meters (33 ft) of stranded patch cable between each jack and the attached device. Since stranded cable has higher attenuation than solid cable, exceeding 10 metres of patch cabling will reduce the permissible length of horizontal cable.
When used for 10GBASE-T, Cat 6 cable's maximum length is 55 meters (180 ft) in a favourable alien crosstalk environment, but only 37 meters (121 ft) in a hostile alien crosstalk environment, such as when many cables are bundled together. However, because the effects of alien crosstalk environments on cables are difficult to determine prior to installation, it is highly recommended that all Cat6 cables being used for 10GBASE-T are electrically tested once installed. With its improved specifications, Cat6A does not have this limitation and can run 10GBASE-T at 100 meters (330 ft) without electronic testing.
Read more about this topic: Category 6 Cable
Famous quotes containing the words maximum and/or length:
“Probably the only place where a man can feel really secure is in a maximum security prison, except for the imminent threat of release.”
—Germaine Greer (b. 1939)
“Baltimore lay very near the immense protein factory of Chesapeake Bay, and out of the bay it ate divinely. I well recall the time when prime hard crabs of the channel species, blue in color, at least eight inches in length along the shell, and with snow-white meat almost as firm as soap, were hawked in Hollins Street of Summer mornings at ten cents a dozen.”