ANSI Device Numbers - List of Device Numbers and Acronyms

List of Device Numbers and Acronyms

  • 1 – Master Element
  • 2 – Time Delay Starting or Closing Relay
  • 3 – Checking or Interlocking Relay
  • 4 – Master Contactor
  • 5 – Stopping Device
  • 6 – Starting Circuit Breaker
  • 7 – Rate of Change Relay
  • 8 – Control Power Disconnecting Device
  • 9 – Reversing Device
  • 10 – Unit Sequence Switch
  • 11 – Multi-function Device
  • 12 – Overspeed Device
  • 13 – Synchronous-speed Device
  • 14 – Underspeed Device
  • 15 – Speed – or Frequency, Matching Device
  • 16 – Data Communications Device
  • 17 – Shunting or Discharge Switch
  • 18 – Accelerating or Decelerating Device
  • 19 – Starting to Running Transition Contactor
  • 20 – Electrically Operated Valve
  • 21 – Distance Relay
  • 22 – Equalizer Circuit Breaker
  • 23 – Temperature Control Device
  • 24 – Volts Per Hertz Relay
  • 25 – Synchronizing or Synchronism-Check Device
  • 26 – Apparatus Thermal Device
  • 27 – Undervoltage Relay
  • 28 – Flame detector
  • 29 – Isolating Contactor or Switch
  • 30 – Annunciator Relay
  • 31 – Separate Excitation Device
  • 32 – Directional Power Relay
  • 33 – Position Switch
  • 34 – Master Sequence Device
  • 35 – Brush-Operating or Slip-Ring Short-Circuiting Device
  • 36 – Polarity or Polarizing Voltage Devices
  • 37 – Undercurrent or Underpower Relay
  • 38 – Bearing Protective Device
  • 39 – Mechanical Condition Monitor
  • 40 – Field (over/under excitation) Relay
  • 41 – Field Circuit Breaker
  • 42 – Running Circuit Breaker
  • 43 – Manual Transfer or Selector Device
  • 44 – Unit Sequence Starting Relay
  • 45 – Abnormal Atmospheric Condition Monitor
  • 46 – Reverse-phase or Phase-Balance Current Relay
  • 47 – Phase-Sequence or Phase-Balance Voltage Relay
  • 48 – Incomplete Sequence Relay
  • 49 – Machine or Transformer, Thermal Relay
  • 50 – Instantaneous Overcurrent Relay
  • 51 – AC Inverse Time Overcurrent Relay
  • 52 – AC Circuit Breaker
  • 53 – Exciter or DC Generator Relay
  • 54 – Turning Gear Engaging Device
  • 55 – Power Factor Relay
  • 56 – Field Application Relay
  • 57 – Short-Circuiting or Grounding Device
  • 58 – Rectification Failure Relay
  • 59 – Overvoltage Relay
  • 60 – Voltage or Current Balance Relay
  • 61 – Density Switch or Sensor
  • 62 – Time-Delay Stopping or Opening Relay
  • 63 – Pressure Switch
  • 64 – Ground Detector Relay
  • 65 – Governor
  • 66 – Notching or Jogging Device
  • 67 – AC Directional Overcurrent Relay
  • 68 – Blocking or "Out-of-Step" Relay
  • 69 – Permissive Control Device
  • 70 – Rheostat
  • 71 – Liquid Level Switch
  • 72 – DC Circuit Breaker
  • 73 – Load-Resistor Contactor
  • 74 – Alarm Relay
  • 75 – Position Changing Mechanism
  • 76 – DC Overcurrent Relay
  • 77 – Telemetering Device
  • 78 – Phase-Angle Measuring Relay
  • 79 – AC Reclosing Relay
  • 80 – Flow Switch
  • 81 – Frequency Relay
  • 82 – DC Reclosing Relay
  • 83 – Automatic Selective Control or Transfer Relay
  • 84 – Operating Mechanism
  • 85 – Communications,Carrier or Pilot-Wire Relay
  • 86 – Lockout Relay
  • 87 – Differential Protective Relay
  • 88 – Auxiliary Motor or Motor Generator
  • 89 – Line Switch
  • 90 – Regulating Device
  • 91 – Voltage Directional Relay
  • 92 – Voltage and Power Directional Relay
  • 93 – Field Changing Contactor
  • 94 – Tripping or Trip-Free Relay
  • 95 – For specific applications where other numbers are not suitable
  • 96 – For specific applications where other numbers are not suitable
  • 97 – For specific applications where other numbers are not suitable
  • 98 – For specific applications where other numbers are not suitable
  • 99 – For specific applications where other numbers are not suitable
  • AFD – Arc Flash Detector
  • CLK – Clock or Timing Source
  • DDR – Dynamic Disturbance Recorder
  • DFR – Digital Fault Recorder
  • ENV – Environmental Data
  • HIZ – High Impedance Fault Detector
  • HMI – Human Machine Interface
  • HST – Historian
  • LGC – Scheme Logic
  • MET – Substation Metering
  • PDC – Phasor Data Concentrator
  • PMU – Phasor Measurement Unit
  • PQM – Power Quality Monitor
  • RIO – Remote Input/Output Device
  • RTU – Remote Terminal Unit/Data Concentrator
  • SER – Sequence of Events Recorder
  • TCM – Trip Circuit Monitor
  • SOTF – Switch On To Fault

Read more about this topic:  ANSI Device Numbers

Famous quotes containing the words list of, list, device and/or numbers:

    Religious literature has eminent examples, and if we run over our private list of poets, critics, philanthropists and philosophers, we shall find them infected with this dropsy and elephantiasis, which we ought to have tapped.
    Ralph Waldo Emerson (1803–1882)

    Modern tourist guides have helped raised tourist expectations. And they have provided the natives—from Kaiser Wilhelm down to the villagers of Chichacestenango—with a detailed and itemized list of what is expected of them and when. These are the up-to- date scripts for actors on the tourists’ stage.
    Daniel J. Boorstin (b. 1914)

    Irony, forsooth! Guard yourself, Engineer, from the sort of irony that thrives up here; guard yourself altogether from taking on their mental attitude! Where irony is not a direct and classic device of oratory, not for a moment equivocal to a healthy mind, it makes for depravity, it becomes a drawback to civilization, an unclean traffic with the forces of reaction, vice and materialism.
    Thomas Mann (1875–1955)

    Think of the earth as a living organism that is being attacked by billions of bacteria whose numbers double every forty years. Either the host dies, or the virus dies, or both die.
    Gore Vidal (b. 1925)