Air Flow Bench - Instrumentation

Instrumentation

Air flow conditions must be measured at two locations, across the test piece and across the metering element. The pressure difference across the test piece allows the standardization of tests from one to another. The pressure across the metering element allows calculation of the actual flow through the whole system.

The pressure across the test piece is typically measured with a U tube manometer while, for increased sensitivity and accuracy, the pressure difference across the metering element is measured with an inclined manometer. One end of each manometer is connected to its respective plenum chamber while the other is open to the atmosphere.

Ordinarily all flow bench manometers measure in inches of water although the inclined manometer's scale is usually replaced with a logarithmic scale reading in percentage of total flow of the selected metering element which makes flow calculation simpler.

Temperature must also be accounted for because the air pump will heat the air passing through it making the air down stream of it less dense and more viscous. This difference must be corrected for. Temperature is measured at the test piece plenum and at the metering element plenum. Correction factors are then applied during flow calculations. Some flow bench designs place the air pump after the metering element so that heating by the air pump is not as large a concern.

Additional manometers can be installed for use with hand held probes, which are used to explore local flow conditions in the port.

Read more about this topic:  Air Flow Bench