AC/DC (electricity) - Electric Power Transmission - The Competing Systems

The Competing Systems

Edison's DC distribution system consisted of generating plants feeding heavy distribution conductors, with customer loads (lighting and motors) tapped off them. The system operated at the same voltage level throughout; for example, 100 volt lamps at the customer's location would be connected to a generator supplying 110 volts, to allow for some voltage drop in the wires between the generator and load. The voltage level was chosen for convenience in lamp manufacture; high-resistance carbon filament lamps could be constructed to withstand 100 volts, and to provide lighting performance economically competitive with gas lighting. At the time it was felt that 100 volts was not likely to present a severe hazard of fatal electric shock.

To save on the cost of copper conductors, a three-wire distribution system was used. The three wires were at +110 volts, 0 volts and −110 volts relative potential. 100-volt lamps could be operated between either the +110 or −110 volt legs of the system and the 0-volt "neutral" conductor, which carried only the unbalanced current between the + and − sources. The resulting three-wire system used less copper wire for a given quantity of electric power transmitted, while still maintaining (relatively) low voltages. However, even with this innovation, the voltage drop due to the resistance of the system conductors was so high that generating plants had to be located within a mile (1.6 km) or so of the load. Higher voltages could not so easily be used with the DC system because there was no efficient low-cost technology that would allow reduction of a high transmission voltage to a low utilization voltage.

In the alternating current system, a transformer was used between the (relatively) high voltage distribution system and the customer loads. Lamps and small motors could still be operated at some convenient low voltage. However, the transformer would allow power to be transmitted at much higher voltages, say, ten times that of the loads. For a given quantity of power transmitted, the wire cross-sectional area would be inversely proportional to the voltage used. Alternatively, the allowable length of a circuit, given a wire size and allowable voltage drop, would increase approximately as the square of the distribution voltage. This had the practical significance that fewer, larger generating plants could serve the load in a given area. Large loads, such as industrial motors or converters for electric railway power, could be served by the same distribution network that fed lighting, by using a transformer with a suitable secondary voltage.

Read more about this topic:  AC/DC (electricity), Electric Power Transmission

Famous quotes containing the words competing and/or systems:

    The idealist’s programme of political or economic reform may be impracticable, absurd, demonstrably ridiculous; but it can never be successfully opposed merely by pointing out that this is the case. A negative opposition cannot be wholly effectual: there must be a competing idealism; something must be offered that is not only less objectionable but more desirable.
    Charles Horton Cooley (1864–1929)

    I am beginning to suspect all elaborate and special systems of education. They seem to me to be built up on the supposition that every child is a kind of idiot who must be taught to think.
    Anne Sullivan (1866–1936)